Square D QO QO115CAFIC Circuit Breaker, AFCI, 15 A, 1 -Pole, 120 V, Fixed Trip, Plug Mounting

Category Fuses
9085606
Call for price
Compare

Square D QO QO115CAFIC Circuit Breaker, AFCI, 15 A, 1 -Pole, 120 V, Fixed Trip, Plug Mounting

Item Code: 9085606
Combination CAFCI 3/4 in single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 VAC. UL listed. Carded.
Category Fuses
Manufacturer SQUARE D
Combination CAFCI 3/4 in single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 VAC. UL listed. Carded.

Specifications

UNSPSC Code

35.353.353

Weight

0.1lb

Height

6.9in

Width

3.7in

Length

4.6in

Current Rating

15 A

Dimensions

2-29/32 in L x 3/4 in W x 4-3/4 in H

Interrupt Rating

10 kA

Mounting Type

Plug

Number of Phases

1

Number Of Poles

1

Terminal Type

Pressure Contact

Trip Type

Fixed

Type

AFCI

Voltage Rating

120 V

Wire Size

12 to 8 14 to 8 AWG

Combination CAFCI 3/4 in single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 VAC. UL listed. Carded.

Specifications

UNSPSC Code

35.353.353

Weight

0.1lb

Height

6.9in

Width

3.7in

Length

4.6in

Current Rating

15 A

Dimensions

2-29/32 in L x 3/4 in W x 4-3/4 in H

Interrupt Rating

10 kA

Mounting Type

Plug

Number of Phases

1

Number Of Poles

1

Terminal Type

Pressure Contact

Trip Type

Fixed

Type

AFCI

Voltage Rating

120 V

Wire Size

12 to 8 14 to 8 AWG