GE THQL2160 Feeder Circuit Breaker, Type THQL, 60 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug

Category Fuses
6122113
Call for price
Starting from
$21.45 / EA
/
- +
Compare

GE THQL2160 Feeder Circuit Breaker, Type THQL, 60 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug

Item Code: 6122113
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).
Category Fuses
Manufacturer ABB
  • Calibration screw is cemented to prevent shifting
  • Case is made of heat-resistant thermoset for stability and structural integrity
  • Tin-plated copper stabs create a reliable, permanent and corrosion-resistant connections
  • Trips to the center position
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).

Specifications

UNSPSC Code

35.353.353

Weight

0.1lb

Height

3.25in

Width

3.75in

Length

11in

Actuator Type

Quick-Make Quick-Break

Brand

GE

Category

FUSES & BREAKERS

Current Rating

60 A

Dimensions

3.28 in L x 2 in W x 2.38 in H

Frame Type

Q-line

Interrupt Rating

10 kA

Mounting Type

Plug

Number of Phases

1

Number Of Poles

2

Operating Frequency

50/60 Hz

Operating Temperature

60 to 75 deg C

Suitable For

Reverse Feed

Terminal Type

Lug

Trip Sensitivity

600 A

Trip Type

Non-Interchangeable

Type

Type THQL

Voltage Rating

120/240 V

Wire Size

8 to 3 8 to 2 AWG

Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 cu or 12-8 al AWG wire, 35 to 60 A 8-3 cu or 8-2 al AWG wire, 70 to 100 A 6-1/0 cu or 4-1/0 al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).

Specifications

UNSPSC Code

35.353.353

Weight

0.1lb

Height

3.25in

Width

3.75in

Length

11in

Actuator Type

Quick-Make Quick-Break

Brand

GE

Category

FUSES & BREAKERS

Current Rating

60 A

Dimensions

3.28 in L x 2 in W x 2.38 in H

Frame Type

Q-line

Interrupt Rating

10 kA

Mounting Type

Plug

Number of Phases

1

Number Of Poles

2

Operating Frequency

50/60 Hz

Operating Temperature

60 to 75 deg C

Suitable For

Reverse Feed

Terminal Type

Lug

Trip Sensitivity

600 A

Trip Type

Non-Interchangeable

Type

Type THQL

Voltage Rating

120/240 V

Wire Size

8 to 3 8 to 2 AWG