Branch: 40 W. Mclemore Ave - (901) 948-4555, Memphis
0 $0.00
items in your cartto quote To cart
Ooops no items were found.
Try something else.
Ok
Loading…

Siemens QF120A Circuit Breaker, GFCI, Type QPF, 20 A, 1 -Pole, 120 V, Plug Mounting

Category Fuses
6929533
Call for price
Starting from
$76.49 / EA
/
- +
Compare

Siemens QF120A Circuit Breaker, GFCI, Type QPF, 20 A, 1 -Pole, 120 V, Plug Mounting

Item Code: 6929533
Ground fault circuit interrupters are an effective means of preventing severe electrical shock. To protect equipment from damaging ground faults, Siemens GFCIs continuously monitor the difference in current between the hot and neutral conductors. If the electricity going to an outlet equals the current coming back from the outlet, the GFCI is dormant. If the electricity going to an outlet is greater than 5 mA than the current coming back from the outlet, the GFCI will open the circuit to stop of flow of electricity.
Category Fuses
Manufacturer SIEMENS
Ground fault circuit interrupters are an effective means of preventing severe electrical shock. To protect equipment from damaging ground faults, Siemens GFCIs continuously monitor the difference in current between the hot and neutral conductors. If the electricity going to an outlet equals the current coming back from the outlet, the GFCI is dormant. If the electricity going to an outlet is greater than 5 mA than the current coming back from the outlet, the GFCI will open the circuit to stop of flow of electricity.

Specifications

UNSPSC Code

35.353.353

Weight

0.1lb

Height

3.1in

Width

4.4in

Length

1.1in

Actuator Type

Magnetic Thermal

Current Rating

20 A

Dimensions

3 in W x 4 in D x 1 in H

Interrupt Rating

10 kA

Mounting Type

Plug

Number Of Poles

1

Operating Frequency

50/60 Hz

Operating Temperature

40 deg C

Terminal Type

Lug

Trip Sensitivity

5 mA

Type

GFCI Type QPF

Voltage Rating

120 V

Wire Size

14 To 10 AWG

Ground fault circuit interrupters are an effective means of preventing severe electrical shock. To protect equipment from damaging ground faults, Siemens GFCIs continuously monitor the difference in current between the hot and neutral conductors. If the electricity going to an outlet equals the current coming back from the outlet, the GFCI is dormant. If the electricity going to an outlet is greater than 5 mA than the current coming back from the outlet, the GFCI will open the circuit to stop of flow of electricity.

Specifications

UNSPSC Code

35.353.353

Weight

0.1lb

Height

3.1in

Width

4.4in

Length

1.1in

Actuator Type

Magnetic Thermal

Current Rating

20 A

Dimensions

3 in W x 4 in D x 1 in H

Interrupt Rating

10 kA

Mounting Type

Plug

Number Of Poles

1

Operating Frequency

50/60 Hz

Operating Temperature

40 deg C

Terminal Type

Lug

Trip Sensitivity

5 mA

Type

GFCI Type QPF

Voltage Rating

120 V

Wire Size

14 To 10 AWG

SEARCH ×