Bussmann BP/FRN-R-50 Time Delay Fuse, 50 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body

Category Fuses
8351504
Call for price
Starting from
$34.75 / EA
/
- +
Compare

Bussmann BP/FRN-R-50 Time Delay Fuse, 50 A, 250 VAC, 125 VDC, 20, 200 kA Interrupt, Fiberglass Body

Item Code: 8351504
Bussmann series Fusetron cartridge fuses are 23% more energy-efficient and offer the ideal time delay performance. Their dual-element feature allows closer sizing to load for excellent protection of motors and transformers. These Class RK5 fuses with a 200 kA interrupting rating can be used in a broad range of applications. When sized correctly, they help protect motors from burnout caused by overloads or single phasing. The time delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present. In addition, the dual-element design opens in as little as 0.004 secs if the fuse experiences short circuit conditions. All fuses are UL listed Class R (IR: 200 kA). Groove in end cap or notch in knife blade permit the fuse to be used in only Class H, Class K or Class R fuse blocks.
Category Fuses
Manufacturer Bussmann
Bussmann series Fusetron cartridge fuses are 23% more energy-efficient and offer the ideal time delay performance. Their dual-element feature allows closer sizing to load for excellent protection of motors and transformers. These Class RK5 fuses with a 200 kA interrupting rating can be used in a broad range of applications. When sized correctly, they help protect motors from burnout caused by overloads or single phasing. The time delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present. In addition, the dual-element design opens in as little as 0.004 secs if the fuse experiences short circuit conditions. All fuses are UL listed Class R (IR: 200 kA). Groove in end cap or notch in knife blade permit the fuse to be used in only Class H, Class K or Class R fuse blocks.

Specifications

UNSPSC Code

35.353.353

Weight

0.1lb

Height

3in

Width

4.5in

Length

6in

Body Material

Fiberglass

Current Rating

50 A

Diameter

13/16 in

Element Type

Dual

Indicator Type

Non-indicating

Interrupt Rating

20 200 kA

Length

3 in

Rejection/Non-Rejection

Rejection

Terminal Type

Ferrule Holder

Type

Cartridge Energy Efficient

Voltage Rating

250 VAC 125 VDC

Bussmann series Fusetron cartridge fuses are 23% more energy-efficient and offer the ideal time delay performance. Their dual-element feature allows closer sizing to load for excellent protection of motors and transformers. These Class RK5 fuses with a 200 kA interrupting rating can be used in a broad range of applications. When sized correctly, they help protect motors from burnout caused by overloads or single phasing. The time delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present. In addition, the dual-element design opens in as little as 0.004 secs if the fuse experiences short circuit conditions. All fuses are UL listed Class R (IR: 200 kA). Groove in end cap or notch in knife blade permit the fuse to be used in only Class H, Class K or Class R fuse blocks.

Specifications

UNSPSC Code

35.353.353

Weight

0.1lb

Height

3in

Width

4.5in

Length

6in

Body Material

Fiberglass

Current Rating

50 A

Diameter

13/16 in

Element Type

Dual

Indicator Type

Non-indicating

Interrupt Rating

20 200 kA

Length

3 in

Rejection/Non-Rejection

Rejection

Terminal Type

Ferrule Holder

Type

Cartridge Energy Efficient

Voltage Rating

250 VAC 125 VDC